How to Choose Aluminum Foil Mylar Tape for Cable Shielding


    Aluminum Foil Mylar Tape is widely used in coaxial cables, LAN cables, electronic communication cables, computer peripheral cables and other products that require interference shielding. However, selecting the material by total thickness alone can lead to the wrong structure, roll format or processing performance. A reliable selection should consider the aluminum/PET composition, mechanical properties, finished width, roll core and the actual cable design.

    This guide explains the key factors a cable manufacturer should confirm before requesting a quotation or approving a sample.

1. What Is Aluminum Foil Mylar Tape?

    Aluminum Foil Mylar Tape, also called Aluminum Polyester Tape or AL/PET Tape, is a composite material made by laminating aluminum foil with polyester film. The aluminum layer provides the conductive surface used in the cable shielding construction, while the PET layer supports the composite mechanically during slitting, wrapping and subsequent cable processing.

    The final product can be slit into narrow rolls and supplied in pad-roll or spool form. Different colors and roll formats may be available depending on the selected grade and confirmed production requirements.

2. Why the AL/PET Structure Matters

    A nominal thickness does not always identify a unique product. Two tapes can have the same total thickness but use different aluminum and polyester layers. This changes the unit weight and can influence mechanical behavior during wrapping.

AL/PET Structure

Total Thickness

Mass per Unit Area

Tensile Strength

Breaking Elongation

7 + 15 μm

25 ± 3 μm

43.0 ± 3 g/m²

≥ 70 MPa

≥ 30%

9 + 12 μm

25 ± 3 μm

44.2 ± 3 g/m²

≥ 70 MPa

≥ 30%

    The values above come from the applicable Tino Material TDS document for the listed 25 μm grades. Because the structures differ, buyers should specify both the AL/PET composition and total thickness rather than requesting only “25 μm.”

3. Key Parameters to Check Before Selection

AL/PET Composition

    The first figure represents the aluminum-foil layer and the second figure represents the polyester-film layer. Confirm the required structure with your cable designer or process engineer, especially when replacing an existing material.

Total Thickness

    Total thickness affects the space occupied by the shielding layer and the handling behavior during wrapping. The suitable thickness should be checked against the cable diameter, shielding design and production equipment.

Mass per Unit Area

    Mass per unit area helps buyers compare materials that have similar nominal thicknesses but different layer structures. Use the grade-specific TDS value rather than assuming that every tape of the same total thickness has the same weight.

Tensile Strength and Breaking Elongation

    These values help indicate how the material behaves during slitting and wrapping. For the 25 μm grades shown above, the listed tensile strength is ≥70 MPa and breaking elongation is ≥30%. Always use the value in the approved TDS for the exact structure ordered.

Finished Width and Tolerance

    The reviewed 25 μm and 30 μm TDS documents list a minimum finished width of 3 mm with a width tolerance of ±0.5 mm. The correct width depends on the cable diameter, wrapping angle and required overlap. Availability should be confirmed for the selected structure and roll format.

Roll-Core Inside Diameter and Maximum Outside Diameter

    For pad-roll supply, the reviewed TDS documents list plastic cores with inside diameters of 52, 55, 76.2 and 80 mm, and a maximum roll outside diameter of 600 mm. Confirm these dimensions against the pay-off unit before ordering.

Pad Roll or Spool

    Pad rolls are suitable for conventional roll supply. Spools can support longer continuous lengths and reduce roll changes when the equipment and process are compatible. The reviewed TDS lists a 76.2 mm spool-core inside diameter, while spool height can be customized on demand.

4. How to Select Aluminum Foil Mylar by Application

Coaxial Cable

    Confirm the conductive-side orientation, finished width, overlap and compatibility with the overall shielding construction. The selected tape should match both the cable design and the wrapping equipment.

LAN and Data Cable

    For LAN and data-cable production, verify the pair or overall shielding design, tape width, winding direction, roll format and the required degree of production continuity. A spool format may be considered when longer continuous processing is required.

Electronic Communication Cable

    Select the AL/PET structure according to the cable’s shielding layout, flexibility target and processing conditions. Do not approve a replacement based only on total thickness.

Computer Peripheral Cable and Other Electronic Products

    Confirm the final cable dimensions, shielding-layer position, bending requirement and termination method. Sampling and production-line testing are recommended before a material change is finalized.

5. Single-Sided and Double-Sided Structures

    Single-sided Aluminum Foil Mylar uses an AL/PET structure, with aluminum foil on one side and polyester film on the other. A double-sided structure generally uses AL/PET/AL, placing aluminum foil on both outer surfaces.

    The correct choice depends on the shielding-layer design, conductive contact requirement, wrapping direction and termination method. Because construction requirements vary, buyers should provide a drawing, current specification or sample when requesting a recommendation.

6. Common Purchasing Mistakes

  • Requesting only the total thickness without specifying the AL/PET structure.
  • Not confirming which side must face outward or contact the drain wire.
  • Ignoring finished width, width tolerance and overlap requirement.
  • Selecting a roll-core size that does not fit the pay-off unit.
  • Ordering pad rolls when the production line requires long continuous spool supply.
  • Assuming that all structures with the same total thickness have identical weight and mechanical behavior.
  • Changing materials without sample validation or a production-line trial.

7. Information to Include in Your RFQ

  • Cable type and application.
  • Single-sided AL/PET or double-sided AL/PET/AL structure.
  • Required aluminum/PET composition or existing material specification.
  • Total thickness and finished width.
  • Conductive-side orientation and wrapping method.
  • Roll-core inside diameter and maximum outside diameter.
  • Pad-roll or spool requirement; spool dimensions if applicable.
  • Color requirement, if any.
  • Order quantity, sample requirement and destination.
  • Existing drawing, TDS or physical sample when requesting a replacement.

8. Handling and Storage

    Handle rolls carefully during transportation to protect the surface and slit edges. Store the material in a dry, ventilated area, away from wet floors and direct sunlight. The reviewed TDS documents specify conventional plastic-bag packing for the listed 25 μm and 30 μm grades.

    MSDS documents for the reviewed 38 μm and 50 μm products state storage at room temperature of 25°C and RH 65%, with ventilation and dry conditions. Storage instructions should be checked against the exact product document supplied with the order.

Frequently Asked Questions

What is Aluminum Foil Mylar Tape used for?

    It is used in coaxial cables, LAN cables, electronic communication cables, computer peripheral cables and other electronic products that require interference shielding.

Is AL/PET structure the same as total thickness?

    No. Total thickness describes the overall composite thickness, while AL/PET structure identifies the individual aluminum and polyester layers. The same total thickness may be available in more than one AL/PET combination.

What is the difference between 7+15 and 9+12?

    Both reviewed grades have a total thickness of 25 ± 3 μm, tensile strength of ≥70 MPa and breaking elongation of ≥30%. Their layer structures and listed mass per unit area differ: 43.0 ± 3 g/m² for 7+15 and 44.2 ± 3 g/m² for 9+12.

Can Aluminum Foil Mylar Tape be supplied in narrow widths?

    The reviewed 25 μm and 30 μm TDS documents list a minimum width of 3 mm with a tolerance of ±0.5 mm. Availability should be confirmed for the selected structure and roll format.

Can it be supplied on spools?

    Yes. The reviewed TDS documents include spool supply with a 76.2 mm inside diameter, and spool height can be customized on demand. Confirm the required spool dimensions and equipment limits before ordering.

How should I choose between single-sided and double-sided tape?

    Choose according to the cable shielding design, required conductive surfaces, wrapping direction and termination method. Provide a drawing or current specification if you need a material recommendation.

Need Help Selecting the Right AL/PET Structure?

    Send Tino Material your cable application, AL/PET structure, total thickness, finished width, conductive-side orientation, roll-core size and required roll format. Our team will review the information and help confirm a suitable specification for sampling and production evaluation.

 

📧 Email:world@dilo-china.com
        My Wechat:  TlNO-Tina or 13694945590
        WhatsApp:+86 13694945590

Related news


Low-Smoke Halogen-Free Flame-Retardant Nonwoven Fabric: A Material Solution for Cable Wrapping, Separation, and Industrial Protection

Has published a technical overview of Low-Smoke Halogen-Free Flame-Retardant Nonwoven Fabric. As an industrial material based on a nonwoven substrate and designed through a specific flame-retardant and low-smoke, halogen-free system, the product may be considered for cable wrapping, interlayer separation, auxiliary insulation, liner protection, and industrial covering according to its specific grade.


Die-Cut Copper Foil Tape: A Customized Material Solution for EMI Shielding, Grounding, and Precision Bonding

Has published a technical overview of Die-Cut Copper Foil Tape. Based on copper foil adhesive tape, die-cut copper foil tape is converted through precision die cutting, matrix stripping, release-liner lamination, and roll or sheet packaging. It can be customized for electronic components, cables, connectors, enclosure seams, and conductive parts that require shaped coverage, localized grounding, EMI/RFI shielding, and accurate positioning.


PI Aluminum Foil: A Composite Material Solution for Cable Shielding, Insulation Separation, and Heat-Resistant Structures

has published a technical overview of PI Aluminum Foil and its potential use in cable wrapping, localized shielding, insulation separation, heat-resistant covering, and electronic-component protection. The term PI Aluminum Foil generally describes a composite, laminated, or coated structure involving aluminum foil and polyimide (PI) film. The exact layer arrangement and adhesive configuration should be verified against the relevant product documentation.


Black Acetate Cloth Adhesive Tape: A Flexible Insulation and Wrapping Material for Harnesses, Coils, and Electronic Components

Tino Material has published a technical overview of Black Acetate Cloth Adhesive Tape and its potential use in wire-harness bundling, coil wrapping, electronic-component fixing, insulation separation, and industrial-part protection. As a flexible adhesive tape with an acetate cloth backing, Black Acetate Cloth Tape can be selected for wrapping and securing wires, harnesses, coils, and irregular surfaces according to its specific construction and adhesive grade.


Industrial Cotton Paper: A Paper-Based Material Solution for Cable Wrapping and Insulation Separation

Tino Material has published a technical overview of Industrial Cotton Paper and its potential use in cable wrapping, insulation separation, and industrial covering structures. As a paper-based roll material, Industrial Cotton Paper can be considered for cable wrapping, interlayer separation, forming assistance, and component protection according to its construction and technical grade. It provides manufacturers with a flexible material option suitable for slitting, unwinding, and continuous wrapping processes.


Tino Material Provides Polyester Yarn and Aluminum Foil Mylar Samples to an Indian Customer for Application Evaluation

Tino Material has provided Polyester Yarn and Aluminum Foil Mylar samples to a customer in India for an initial evaluation of material construction, processing compatibility, insulation separation, and cable-related applications. The sample discussion will help the customer assess how Polyester Yarn and Aluminum Foil Mylar may fit its product design and manufacturing process for selected cable and electronic-material structures.